↓ Skip to main content

Repositionable Vascular Occluder: Experimental Comparison with Standard Gianturco Coils

Overview of attention for article published in Journal of Vascular and Interventional Radiology, September 1996
Altmetric Badge

About this Attention Score

  • Good Attention Score compared to outputs of the same age (69th percentile)
  • Average Attention Score compared to outputs of the same age and source

Mentioned by

patent
26 patents

Readers on

mendeley
6 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Repositionable Vascular Occluder: Experimental Comparison with Standard Gianturco Coils
Published in
Journal of Vascular and Interventional Radiology, September 1996
DOI 10.1016/s1051-0443(96)70831-x
Pubmed ID
Authors
Abstract

To evaluate the efficacy and recanalization rates of a newly designed vascular occlusion device. The self-expanding vascular occluder was braided from fine nitinol wires and filled with polyester fibers. The device was delivered through a 6-F polyethylene introducing sheath with use of a delivery cable with a microscrew adaptor. Comparison was made between one occlusion plug and two Gianturco coils placed in the corresponding contralateral arterial segment in nine dogs and six pigs. The mean diameter of the targeted vessels was 4.8 mm +/- 0.8. Two animals were killed immediately after occlusion, and the remaining 13 animals underwent follow-up angiography at 1 week and/or 1 month, after which the animals were killed and the vessels were explanted for gross and histopathologic examination. Significantly shorter time-to-occlusion was achieved with the nitinol plug compared with two Gianturco coils (1.73 minutes +/- 1.28 vs 5.73 minutes +/- 6.18; P = .021). The recanalization rate at 1 month was also significantly lower (36.4% vs 81.8%, P = .027). The occlusion time was strongly dependent on the target artery diameter with Gianturco coils (R = .79, P = .0007), and not with the nitinol plug. The nitinol vascular occluder appears highly effective and reliable, with one plug resulting in significantly faster and longer lasting occlusions compared with two Gianturco coils. The new device can be repositioned prior to release, therefore allowing optimal positioning.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 6 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Unknown 6 100%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Researcher 2 33%
Professor 1 17%
Student > Master 1 17%
Unknown 2 33%
Readers by discipline
Readers by discipline Count As %
Medicine and Dentistry 3 50%
Environmental Science 1 17%
Unknown 2 33%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 6. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 12 November 2019.
All research outputs
#6,589,825
of 30,598,342 outputs
Outputs from Journal of Vascular and Interventional Radiology
#1,769
of 5,033 outputs
Outputs of similar age
#5,694
of 34,896 outputs
Outputs of similar age from Journal of Vascular and Interventional Radiology
#1
of 6 outputs
Altmetric has tracked 30,598,342 research outputs across all sources so far. This one has received more attention than most of these and is in the 74th percentile.
So far Altmetric has tracked 5,033 research outputs from this source. They typically receive more attention than average, with a mean Attention Score of 8.4. This one has gotten more attention than average, scoring higher than 57% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 34,896 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 69% of its contemporaries.
We're also able to compare this research output to 6 others from the same source and published within six weeks on either side of this one. This one has scored higher than all of them