Assessment of Small-Diameter Aortic Mechanical Prostheses

Overview of attention for article published in Circulation, September 1998
Altmetric Badge

Mentioned by

patent
52 patents

Readers on

mendeley
7 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Assessment of Small-Diameter Aortic Mechanical Prostheses
Published in
Circulation, September 1998
DOI 10.1161/01.cir.98.9.866
Pubmed ID
Authors

Richard H. Marcus, Russell S. Heinrich, James Bednarz, Stephen Lupovitch, Joseph Abruzzo, Raphael Borok, Byron Vandenberg, Richard E. Kerber, William Piccione, Ajit P. Yoganathan, Roberto M. Lang

Abstract

Noninvasive assessment of functionally stenotic small-diameter aortic mechanical prostheses is complicated by theoretical constraints relating to the hemodynamic relevance of Doppler-derived transprosthetic gradients. To establish the utility of Doppler echocardiography for evaluation of these valves, 20-mm Medtronic Hall and 19-mm St Jude prostheses were studied in vitro and in vivo. Relations between the orifice transprosthetic gradient (equivalent to Doppler), the downstream gradient in the zone of recovered pressure (equivalent to catheter), and fluid mechanical energy losses were examined in vitro. Pressure-flow relations across the 2 prostheses were evaluated by Doppler echocardiography in vivo. For both types of prosthesis in vitro, the orifice was higher than the downstream gradient (P<0.001), and fluid mechanical energy losses were as strongly correlated with orifice as with downstream pressure gradients (r2=0.99 for both). Orifice and downstream gradients were higher and fluid mechanical energy losses were larger for the St Jude than the Medtronic Hall valve (all P<0.001). Whereas estimated effective orifice areas for the 2 valves in vivo were not significantly different, model-independent dynamic analysis of pressure-flow relations revealed higher gradients for the St Jude than the Medtronic Hall valve at a given flow rate (P<0.05). Even in the presence of significant pressure recovery, the Doppler-derived gradient across small-diameter aortic mechanical prostheses does have hemodynamic relevance insofar as it reflects myocardial energy expenditure. Small differences in function between stenotic aortic mechanical prostheses, undetectable by conventional orifice area estimations, can be identified by dynamic Doppler echocardiographic analysis of pressure-flow relations.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 7 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Unknown 7 100%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Ph. D. Student 1 14%
Professor > Associate Professor 1 14%
Student > Bachelor 1 14%
Student > Postgraduate 1 14%
Unknown 3 43%
Readers by discipline
Readers by discipline Count As %
Medicine and Dentistry 2 29%
Social Sciences 1 14%
Unknown 4 57%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 3. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 02 June 2026.
All research outputs
#7,734,518
of 23,524,722 outputs
Outputs from Circulation
#11,321
of 19,920 outputs
Outputs of similar age
#9,970
of 32,400 outputs
Outputs of similar age from Circulation
#48
of 101 outputs
Altmetric has tracked 23,524,722 research outputs across all sources so far. This one is in the 44th percentile – i.e., 44% of other outputs scored the same or lower than it.
So far Altmetric has tracked 19,920 research outputs from this source. They typically receive a lot more attention than average, with a mean Attention Score of 29.9. This one is in the 17th percentile – i.e., 17% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 32,400 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 9th percentile – i.e., 9% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 101 others from the same source and published within six weeks on either side of this one. This one is in the 10th percentile – i.e., 10% of its contemporaries scored the same or lower than it.