↓ Skip to main content

Clinical Performance of an In-Line Point-of-Care Monitor in Neonates

Overview of attention for article published in Pediatrics, September 2000

Mentioned by

patent
102 patents

Readers on

mendeley
30 Mendeley

Citations

dimensions_citation
Loading…
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Clinical Performance of an In-Line Point-of-Care Monitor in Neonates
Published in
Pediatrics, September 2000
DOI 10.1542/peds.106.3.497
Pubmed ID
Authors
Abstract

To evaluate the bias, precision, and blood loss characteristics of an ex vivo in-line point-of-care testing blood gas and electrolyte monitor designed for use in critically ill newborn infants. Study participants included consecutive neonates with an umbilical artery catheter (UAC) in use for clinical laboratory testing. The in-line monitor (VIA LVM Blood Gas and Chemistry Monitoring System, VIA Medical, San Diego, CA) was directly connected to the participant's UAC and the monitor's determinations of pH, PCO(2), PO(2), sodium, potassium, and hematocrit (Hct) were compared with those simultaneously drawn and measured with a standard bench top laboratory instrument (Radiometer 625 ABL; Radiometer America, Inc, Westlake, OH). The bias (the mean difference from the reference method) and precision (1 standard deviation of the mean difference) performance criteria of the in-line monitor were derived using standard laboratory procedures. Sixteen neonates monitored for a total of 37 days had a total of 229 paired blood samples available for comparison by the 2 methods. Bias and precision performance characteristics of the in-line monitor were similar to reports of other point-of-care devices (ie, pH: -.003 +/-.024; PCO(2):.35 +/- 2.84 mm Hg; PO(2):.39 +/- 7.30 mm Hg; sodium:.52 +/- 2.34 mmol/L; potassium:.17 +/-.18 mmol/L; and Hct:.61 +/- 2.80%). The range of values observed for each parameter included much of the range anticipated among critically ill neonates (ie, pH: 7.15-7.65; PCO(2): 25-75 mm Hg; PO(2): 25-275 mm Hg; sodium: 127-150 mmol/L; potassium: 2.6-5.5 mmol/L; and Hct: 32%-60%). Mean blood loss (+/- standard deviation) per sample with the in-line monitor was approximately one-tenth that of the reference method: 24 +/- 7 microL versus 250 microL, respectively. There was no evidence of hemolysis and no patient related safety issues were identified with use of the in-line monitor. Repeated laboratory testing of critically ill neonates using an ex vivo in-line monitor designed for use in neonates provides reliable laboratory results. The blood loss and hemolysis data obtained suggests that this monitoring device offers potential for reducing neonatal blood loss-and possibly transfusion needs-during the first weeks of life. Before this promising technology can be routinely recommended for care of critically ill neonates, greater practical experience in a variety of clinical settings is needed.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 30 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
United States 2 7%
Australia 1 3%
Austria 1 3%
Unknown 26 87%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Ph. D. Student 6 20%
Other 5 17%
Researcher 4 13%
Student > Postgraduate 3 10%
Student > Doctoral Student 2 7%
Other 4 13%
Unknown 6 20%
Readers by discipline
Readers by discipline Count As %
Medicine and Dentistry 14 47%
Nursing and Health Professions 2 7%
Engineering 2 7%
Biochemistry, Genetics and Molecular Biology 1 3%
Agricultural and Biological Sciences 1 3%
Other 1 3%
Unknown 9 30%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 3. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 20 October 2026.
All research outputs
#8,537,346
of 25,377,790 outputs
Outputs from Pediatrics
#11,042
of 17,844 outputs
Outputs of similar age
#12,949
of 37,745 outputs
Outputs of similar age from Pediatrics
#40
of 77 outputs
Altmetric has tracked 25,377,790 research outputs across all sources so far. This one is in the 43rd percentile – i.e., 43% of other outputs scored the same or lower than it.
So far Altmetric has tracked 17,844 research outputs from this source. They typically receive a lot more attention than average, with a mean Attention Score of 49.6. This one is in the 22nd percentile – i.e., 22% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 37,745 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 10th percentile – i.e., 10% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 77 others from the same source and published within six weeks on either side of this one. This one is in the 7th percentile – i.e., 7% of its contemporaries scored the same or lower than it.