↓ Skip to main content

Noncontact Trephination of the Cornea Using a Pulsed Hydrogen Fluoride Laser

Overview of attention for article published in American Journal of Ophthalmology, November 1987
Altmetric Badge

Mentioned by

patent
22 patents

Readers on

mendeley
3 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Noncontact Trephination of the Cornea Using a Pulsed Hydrogen Fluoride Laser
Published in
American Journal of Ophthalmology, November 1987
DOI 10.1016/s0002-9394(14)74103-0
Pubmed ID
Authors
Abstract

We used a pulsed hydrogen fluoride infrared laser and a specially designed axicon lens to perform circular corneal trephinations in ten eye bank eyes. This noncontact system focused each laser pulse into an annulus on the cornea. Corneal perforation was achieved in seven to nine seconds at a repetition rate of 10 Hz, using a laser output energy of 100 mJ per pulse. A trephination, 90% of corneal thickness, 6.5 mm in diameter, was produced with 70 pulses.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 3 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Unknown 3 100%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Postgraduate 1 33%
Unknown 2 67%
Readers by discipline
Readers by discipline Count As %
Medicine and Dentistry 1 33%
Unknown 2 67%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 3. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 24 November 2020.
All research outputs
#9,515,244
of 27,777,630 outputs
Outputs from American Journal of Ophthalmology
#2,197
of 7,160 outputs
Outputs of similar age
#4,319
of 13,530 outputs
Outputs of similar age from American Journal of Ophthalmology
#4
of 9 outputs
Altmetric has tracked 27,777,630 research outputs across all sources so far. This one is in the 42nd percentile – i.e., 42% of other outputs scored the same or lower than it.
So far Altmetric has tracked 7,160 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 5.3. This one is in the 42nd percentile – i.e., 42% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 13,530 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 7th percentile – i.e., 7% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 9 others from the same source and published within six weeks on either side of this one. This one has scored higher than 5 of them.