↓ Skip to main content

Residual and Dynamic Range of Retinal Nerve Fiber Layer Thickness in Glaucoma: Comparison of Three OCT PlatformsRNFL Residual and Dynamic Range in Glaucoma

Overview of attention for article published in Investigative Ophthalmology & Visual Science, October 2015
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (87th percentile)
  • High Attention Score compared to outputs of the same age and source (96th percentile)

Mentioned by

twitter
4 X users
guideline
1 clinical guideline source
podcasts
1 podcast

Readers on

mendeley
72 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Residual and Dynamic Range of Retinal Nerve Fiber Layer Thickness in Glaucoma: Comparison of Three OCT PlatformsRNFL Residual and Dynamic Range in Glaucoma
Published in
Investigative Ophthalmology & Visual Science, October 2015
DOI 10.1167/iovs.15-17248
Pubmed ID
Authors
Abstract

To estimate visual field (VF) sensitivity at which retinal nerve fiber layer (RNFL) thinning reaches the measurement floor and at which RNFL stops thinning (change points), the dynamic range of RNFL thickness, and the number of steps from normal to RNFL floor among three optical coherence tomography (OCT) devices. Glaucomatous patients (n = 58) and healthy subjects (n = 55-60) prospectively underwent VF testing and RNFL thickness measurement with Cirrus, Spectralis, and RTVue. Change points and corresponding RNFL thicknesses were estimated with simple linear regression (SLR) and Bayesian change point (BCP) analyses. The dynamic range and number of steps to RNFL floor were determined. The average VF change points and corresponding residual thickness at the time RNFL stopped thinning were -22.2 dB and 57.0 μm (Cirrus), -25.3 dB and 49.2 μm (Spectralis), and -24.6 dB and 64.7 μm (RTVue). The RNFL dynamic ranges derived from SLR values were wider on Spectralis (52.6 μm) than on Cirrus (35.4 μm) and RTVue (35.5 μm); the corresponding number of steps to reach the RNFL floor were 9.0 on Cirrus, 10.6 on Spectralis, and 8.3 on RTVue. The relative VF sensitivity at which average RNFL thickness reaches the measurement floor, the residual layer thickness, and RNFL dynamic measurement range differ among the three devices. However, the number of steps from normal to the RNFL thickness floor is comparable.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profiles of 4 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 72 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Unknown 72 100%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Other 9 13%
Student > Ph. D. Student 9 13%
Researcher 8 11%
Professor > Associate Professor 5 7%
Student > Doctoral Student 4 6%
Other 10 14%
Unknown 27 38%
Readers by discipline
Readers by discipline Count As %
Medicine and Dentistry 31 43%
Unspecified 2 3%
Biochemistry, Genetics and Molecular Biology 2 3%
Nursing and Health Professions 2 3%
Computer Science 1 1%
Other 2 3%
Unknown 32 44%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 13. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 07 September 2022.
All research outputs
#3,607,613
of 34,457,357 outputs
Outputs from Investigative Ophthalmology & Visual Science
#628
of 13,298 outputs
Outputs of similar age
#38,035
of 314,613 outputs
Outputs of similar age from Investigative Ophthalmology & Visual Science
#5
of 137 outputs
Altmetric has tracked 34,457,357 research outputs across all sources so far. Compared to these this one has done well and is in the 89th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 13,298 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 5.2. This one has done particularly well, scoring higher than 95% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 314,613 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 87% of its contemporaries.
We're also able to compare this research output to 137 others from the same source and published within six weeks on either side of this one. This one has done particularly well, scoring higher than 96% of its contemporaries.