Accelerated exponential parameterization of T2 relaxation with model‐driven low rank and sparsity priors (MORASA)

Overview of attention for article published in Magnetic Resonance in Medicine, January 2016

Mentioned by

twitter
1 X user

Readers on

mendeley
51 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Accelerated exponential parameterization of T2 relaxation with model‐driven low rank and sparsity priors (MORASA)
Published in
Magnetic Resonance in Medicine, January 2016
DOI 10.1002/mrm.26083
Pubmed ID
Authors
Abstract

This work is to develop a novel image reconstruction method from highly undersampled multichannel acquisition to reduce the scan time of exponential parameterization of T2 relaxation. On top of the low-rank and joint-sparsity constraints, we propose to exploit the linear predictability of the T2 exponential decay to further improve the reconstruction of the T2-weighted images from undersampled acquisitions. Specifically, the exact rank prior (i.e., number of non-zero singular values) is adopted to enforce the spatiotemporal low rankness, while the mixed L2-L1 norm of the wavelet coefficients is used to promote joint sparsity, and the Hankel low-rank approximation is used to impose linear predictability, which integrates the exponential behavior of the temporal signal into the reconstruction process. An efficient algorithm is adopted to solve the reconstruction problem, where corresponding nonlinear filtering operations are performed to enforce corresponding priors in an iterative manner. Both simulated and in vivo datasets with multichannel acquisition were used to demonstrate the feasibility of the proposed method. Experimental results have shown that the newly introduced linear predictability prior improves the reconstruction quality of the T2-weighted images and benefits the subsequent T2 mapping by achieving high-speed, high-quality T2 mapping compared with the existing fast T2 mapping methods. This work proposes a novel fast T2 mapping method integrating the linear predictable property of the exponential decay into the reconstruction process. The proposed technique can effectively improve the reconstruction quality of the state-of-the-art fast imaging method exploiting image sparsity and spatiotemporal low rankness. Magn Reson Med, 2016. © 2016 Wiley Periodicals, Inc.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 51 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
United States 1 2%
Unknown 50 98%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Ph. D. Student 17 33%
Researcher 9 18%
Student > Postgraduate 4 8%
Student > Master 3 6%
Student > Doctoral Student 2 4%
Other 6 12%
Unknown 10 20%
Readers by discipline
Readers by discipline Count As %
Engineering 16 31%
Physics and Astronomy 8 16%
Medicine and Dentistry 4 8%
Mathematics 3 6%
Neuroscience 2 4%
Other 3 6%
Unknown 15 29%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 15 January 2016.
All research outputs
#22,012,573
of 24,558,777 outputs
Outputs from Magnetic Resonance in Medicine
#6,329
of 7,062 outputs
Outputs of similar age
#345,474
of 405,619 outputs
Outputs of similar age from Magnetic Resonance in Medicine
#67
of 104 outputs
Altmetric has tracked 24,558,777 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 7,062 research outputs from this source. They receive a mean Attention Score of 4.4. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 405,619 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 104 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.