↓ Skip to main content

Physical aspects of a real-time tumor-tracking system for gated radiotherapy

Overview of attention for article published in International Journal of Radiation Oncology, Biology, Physics, November 2000
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (88th percentile)
  • High Attention Score compared to outputs of the same age and source (93rd percentile)

Mentioned by

patent
8 patents

Readers on

mendeley
214 Mendeley
citeulike
1 CiteULike
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Physical aspects of a real-time tumor-tracking system for gated radiotherapy
Published in
International Journal of Radiation Oncology, Biology, Physics, November 2000
DOI 10.1016/s0360-3016(00)00748-3
Pubmed ID
Authors
Abstract

To reduce uncertainty due to setup error and organ motion during radiotherapy of tumors in or near the lung, by means of real-time tumor tracking and gating of a linear accelerator. The real-time tumor-tracking system consists of four sets of diagnostic X-ray television systems (two of which offer an unobstructed view of the patient at any time), an image processor unit, a gating control unit, and an image display unit. The system recognizes the position of a 2.0-mm gold marker in the human body 30 times per second using two X-ray television systems. The marker is inserted in or near the tumor using image guided implantation. The linear accelerator is gated to irradiate the tumor only when the marker is within a given tolerance from its planned coordinates relative to the isocenter. The accuracy of the system and the additional dose due to the diagnostic X-ray were examined in a phantom, and the geometric performance of the system was evaluated in 4 patients. The phantom experiment demonstrated that the geometric accuracy of the tumor-tracking system is better than 1.5 mm for moving targets up to a speed of 40 mm/s. The dose due to the diagnostic X-ray monitoring ranged from 0.01% to 1% of the target dose for a 2.0-Gy irradiation of a chest phantom. In 4 patients with lung cancer, the range of the coordinates of the tumor marker during irradiation was 2.5-5.3 mm, which would have been 9.6-38.4 mm without tracking. We successfully implemented and applied a tumor-tracking and gating system. The system significantly improves the accuracy of irradiation of targets in motion at the expense of an acceptable amount of diagnostic X-ray exposure.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 214 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Geographical breakdown
Country Count As %
Japan 2 <1%
Germany 2 <1%
Canada 2 <1%
Latvia 1 <1%
Greece 1 <1%
United Kingdom 1 <1%
China 1 <1%
Australia 1 <1%
Austria 1 <1%
Other 0 0%
Unknown 202 94%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Ph. D. Student 41 19%
Researcher 40 19%
Student > Master 32 15%
Professor > Associate Professor 18 8%
Other 13 6%
Other 33 15%
Unknown 37 17%
Readers by discipline
Readers by discipline Count As %
Physics and Astronomy 57 27%
Medicine and Dentistry 46 21%
Engineering 32 15%
Computer Science 16 7%
Agricultural and Biological Sciences 4 2%
Other 7 3%
Unknown 52 24%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 12. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 02 December 2025.
All research outputs
#3,783,552
of 34,410,315 outputs
Outputs from International Journal of Radiation Oncology, Biology, Physics
#1,735
of 15,466 outputs
Outputs of similar age
#4,709
of 60,517 outputs
Outputs of similar age from International Journal of Radiation Oncology, Biology, Physics
#2
of 59 outputs
Altmetric has tracked 34,410,315 research outputs across all sources so far. Compared to these this one has done well and is in the 88th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 15,466 research outputs from this source. They typically receive more attention than average, with a mean Attention Score of 8.3. This one has done well, scoring higher than 87% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 60,517 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 88% of its contemporaries.
We're also able to compare this research output to 59 others from the same source and published within six weeks on either side of this one. This one has done particularly well, scoring higher than 93% of its contemporaries.