↓ Skip to main content

Development of a highly specific enzyme immunoassay for oxytocin and its use in plasma samples

Overview of attention for article published in Annals of Clinical Biochemistry, September 2016
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (86th percentile)
  • High Attention Score compared to outputs of the same age and source (96th percentile)

Mentioned by

twitter
2 X users
patent
4 patents

Readers on

mendeley
38 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Development of a highly specific enzyme immunoassay for oxytocin and its use in plasma samples
Published in
Annals of Clinical Biochemistry, September 2016
DOI 10.1177/0004563216645122
Pubmed ID
Authors
Abstract

The peptide hormone oxytocin acts in the central nervous system and plays an important role in various complex social behaviors. We report the production of a high affinity and specificity antibody for oxytocin and its use in a highly sensitive enzyme immunoassay (EIA). Biotin that was chemically bound to oxytocin derivative containing zero to six lysines as bridge was the labeled antigen. Seven labeled antigens were used to develop a highly sensitive EIA. Anti-oxytocin antiserum was obtained by immunization of oxytocin-bovine thyrogloblin conjugate to rabbit.Oxytocin sample was added to the second antibody coated microtiter plate and allowed to react overnight at 4°C, then biotinylated oxytocin was added 1 hour at 4°C, and HRP labeled avidin was added and incubated for 1 hours at room temperature. The plate was then washed. HRP activity was measured by a colorimetric method using o-phenylenediamine (490nm). The sensitivity of the EIA improved as the number of lysine residues increased; consequently, biotinylated oxytocin bridged with five lysines was used. A standard curve for oxytocin ranged from 1.0 to 1000 pg/assay. The detection limit of the assay was 2.36 pg, and the reproducibility was 3.18% as CV% (n=5). Cross-reactivity with vasopressin and vasotocin was less than 0.01%. The sensitivity of the EIA could be improved by increasing the number of lysine residues on the biotin-labeled antigen. The proposed method is sensitive and more specific than conventional immunoassays for oxytocin and can be used to determine plasma oxytocin levels.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 38 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Unknown 38 100%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Ph. D. Student 6 16%
Student > Master 6 16%
Researcher 6 16%
Student > Bachelor 4 11%
Professor 2 5%
Other 4 11%
Unknown 10 26%
Readers by discipline
Readers by discipline Count As %
Psychology 10 26%
Nursing and Health Professions 3 8%
Medicine and Dentistry 3 8%
Neuroscience 3 8%
Biochemistry, Genetics and Molecular Biology 2 5%
Other 5 13%
Unknown 12 32%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 13. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 29 September 2026.
All research outputs
#3,631,520
of 34,528,520 outputs
Outputs from Annals of Clinical Biochemistry
#76
of 1,738 outputs
Outputs of similar age
#44,549
of 335,085 outputs
Outputs of similar age from Annals of Clinical Biochemistry
#2
of 64 outputs
Altmetric has tracked 34,528,520 research outputs across all sources so far. Compared to these this one has done well and is in the 89th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 1,738 research outputs from this source. They receive a mean Attention Score of 4.3. This one has done particularly well, scoring higher than 95% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 335,085 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 86% of its contemporaries.
We're also able to compare this research output to 64 others from the same source and published within six weeks on either side of this one. This one has done particularly well, scoring higher than 96% of its contemporaries.