↓ Skip to main content

Enzyme-Immobilized 3D-Printed Reactors for Online Monitoring of Rat Brain Extracellular Glucose and Lactate

Overview of attention for article published in Analytical Chemistry, May 2016
Altmetric Badge

About this Attention Score

  • Above-average Attention Score compared to outputs of the same age (62nd percentile)
  • Above-average Attention Score compared to outputs of the same age and source (58th percentile)

Mentioned by

twitter
1 X user
patent
2 patents

Readers on

mendeley
88 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Enzyme-Immobilized 3D-Printed Reactors for Online Monitoring of Rat Brain Extracellular Glucose and Lactate
Published in
Analytical Chemistry, May 2016
DOI 10.1021/acs.analchem.6b00272
Pubmed ID
Authors
Abstract

In this study we constructed a highly sensitive system for in vivo monitoring of the concentrations of rat brain extracellular glucose and lactate. This system involved microdialysis (MD) sampling and fluorescence determination in conjunction with a novel sample derivatization scheme in which glucose oxidase and lactate oxidase were immobilized in ABS flow bioreactors (manufactured through low-cost three-dimensional printing (3DP)), via fused deposition modeling, for online oxidization of sampled glucose and lactate, respectively, in rat brain microdialysate. After optimizing the experimental conditions for MD sampling, the manufacture of the designed flow reactors, the enzyme immobilization procedure, and the online derivatization scheme, the available sampling frequency was 15 h(-1) and the system's detection limits reached as low as 0.060 mM for glucose and 0.059 mM for lactate, based on a 20-μL conditioned microdialysate; these characteristics were sufficient to reliably determine the concentrations of extracellular glucose and lactate in the brains of living rats. To demonstrate the system's applicability, we performed (i) spike analyses of offline-collected rat brain microdialysate and (ii) in vivo dynamic monitoring of the extracellular glucose and lactate in living rat brains, in addition to triggering neuronal depolarization by perfusing a high-K(+) medium from the implanted MD probe. Our analytical results and demonstrations confirm that postprinting functionalization of analytical devices manufactured using 3DP technology can be a powerful strategy for extending the diversity and adaptability of currently existing analytical configurations.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 88 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Finland 1 1%
Unknown 87 99%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Ph. D. Student 22 25%
Researcher 11 13%
Student > Doctoral Student 6 7%
Professor 6 7%
Student > Bachelor 5 6%
Other 13 15%
Unknown 25 28%
Readers by discipline
Readers by discipline Count As %
Chemistry 18 20%
Engineering 9 10%
Chemical Engineering 7 8%
Agricultural and Biological Sciences 6 7%
Materials Science 4 5%
Other 12 14%
Unknown 32 36%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 4. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 06 April 2021.
All research outputs
#11,297,715
of 33,351,181 outputs
Outputs from Analytical Chemistry
#13,477
of 34,866 outputs
Outputs of similar age
#123,098
of 336,372 outputs
Outputs of similar age from Analytical Chemistry
#102
of 258 outputs
Altmetric has tracked 33,351,181 research outputs across all sources so far. This one has received more attention than most of these and is in the 65th percentile.
So far Altmetric has tracked 34,866 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 5.3. This one has gotten more attention than average, scoring higher than 60% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 336,372 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 62% of its contemporaries.
We're also able to compare this research output to 258 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 58% of its contemporaries.