Abstract

To understand the effective radiation dose during percutaneous cryoablation (CA) and radiofrequency ablation (RFA) and characterize variables which may affect individual dose. Effective radiation dose was determined by conversion of the dose-length product (DLP) from CT scans performed during percutaneous cryoablation (CA) or radiofrequency ablation (RFA) for patients with solitary renal masses (<4cm) at 4 academic centers. Radiation dose per case was compared between patients and institutions using multivariate and univariate analysis. Lifetime attributable risk (LAR) of cancer was calculated for each institution and utilized to determine the number needed to harm (NNH) for a range of ages at the time of exposure. One hundred twenty-three patients met inclusion criteria with a mean age of 71 years. Sixty-nine percent of patients were male, mean BMI was 29.4, and mean tumor size was 2.2 cm. The mean effective radiation dose per ablation was 40 mSv (range 3.7-147). On multivariate analysis only BMI and institution were associated with radiation dose. No significant difference in radiation exposure was seen for RFA or CA procedures. Radiation exposure during percutaneous ablation is similar to a multi-phase CT scan. However, there is wide variability in individual treatment exposure, varying from 3.7-147 mSv, depending primarily on institution and BMI. Standardization of protocols is required in order to achieve as low as reasonably achievable (ALARA) levels of radiation.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 15 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Unknown 15 100%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Master 3 20%
Other 2 13%
Professor 2 13%
Student > Ph. D. Student 2 13%
Professor > Associate Professor 2 13%
Other 1 7%
Unknown 3 20%
Readers by discipline
Readers by discipline Count As %
Medicine and Dentistry 6 40%
Arts and Humanities 1 7%
Nursing and Health Professions 1 7%
Unknown 7 47%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 01 July 2016.
All research outputs
#22,760,732
of 25,377,790 outputs
Outputs from Journal of Endourology
#1,968
of 2,042 outputs
Outputs of similar age
#235,716
of 275,484 outputs
Outputs of similar age from Journal of Endourology
#15
of 16 outputs
Altmetric has tracked 25,377,790 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 2,042 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 5.2. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 275,484 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 16 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.