Accuracy of dose planning for prostate radiotherapy in the presence of metallic implants evaluated by electron spin resonance dosimetry

Overview of attention for article published in Brazilian Journal of Medical and Biological Research, July 2015
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
6 Dimensions

Readers on

mendeley
18 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Accuracy of dose planning for prostate radiotherapy in the presence of metallic implants evaluated by electron spin resonance dosimetry
Published in
Brazilian Journal of Medical and Biological Research, July 2015
DOI 10.1590/1414-431x20154367
Pubmed ID
Authors

G.G. Alves, A. Kinoshita, H.F. de Oliveira, F.S. Guimarães, L.L. Amaral, O. Baffa

Abstract

Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 18 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Brazil 2 11%
Unknown 16 89%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 4 22%
Student > Master 3 17%
Professor 3 17%
Other 2 11%
Researcher 2 11%
Other 3 17%
Unknown 1 6%
Readers by discipline Count As %
Medicine and Dentistry 5 28%
Physics and Astronomy 3 17%
Engineering 2 11%
Nursing and Health Professions 1 6%
Computer Science 1 6%
Other 4 22%
Unknown 2 11%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 30 November 2015.
All research outputs
#20,660,571
of 25,377,790 outputs
Outputs from Brazilian Journal of Medical and Biological Research
#901
of 1,254 outputs
Outputs of similar age
#202,785
of 277,618 outputs
Outputs of similar age from Brazilian Journal of Medical and Biological Research
#14
of 23 outputs
Altmetric has tracked 25,377,790 research outputs across all sources so far. This one is in the 10th percentile – i.e., 10% of other outputs scored the same or lower than it.
So far Altmetric has tracked 1,254 research outputs from this source. They receive a mean Attention Score of 4.9. This one is in the 18th percentile – i.e., 18% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 277,618 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 14th percentile – i.e., 14% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 23 others from the same source and published within six weeks on either side of this one. This one is in the 26th percentile – i.e., 26% of its contemporaries scored the same or lower than it.