↓ Skip to main content

Advancement in liver laparoscopic resection – development of a new surgical device

Overview of attention for article published in Brazilian Journal of Medical and Biological Research, January 2018
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age and source

Mentioned by

twitter
2 X users

Citations

dimensions_citation
1 Dimensions

Readers on

mendeley
10 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Advancement in liver laparoscopic resection – development of a new surgical device
Published in
Brazilian Journal of Medical and Biological Research, January 2018
DOI 10.1590/1414-431x20176062
Pubmed ID
Authors

P. Vavra, L. Karnik, M. Skrobankova, J. Jurcikova, P. Ihnat, P. Zonca, M. Peteja, A. El-Gendi, S. Czudek

Abstract

Liver resection is the standard treatment for any liver lesion. Laparoscopic liver resection is associated with lower intra-operative blood loss and fewer complications than open resection. Access to the posterior part of the right liver lobe is very uncomfortable and difficult for surgeons due the anatomic position, especially when employing laparoscopic surgery. Based on these experiences, a new laparoscopic device was developed that is capable of bending its long axis and allowing the application of radiofrequency energy in areas that were not technically accessible. The device is equipped with four telescopic needle electrodes that cause tissue coagulation after the delivery of radiofrequency energy. Ex vivo testing was performed in 2012 and 2014 at the University Hospital, Ostrava, on a porcine liver tissue. The main goal of this testing was to verify if the newly proposed electrode layout was suitable for sufficient tissue coagulation and creating a safety zone around lesions. During the ex vivo testing, the material of needle electrodes was improved to achieve the lowest possibility of adhesion. The power supply was adjusted from 20 to 120 W and the ablation time, which varied from 10 to 110 s, was monitored. Subsequently, optimal power delivery and time for coagulation was determined. This experimental study demonstrated the feasibility and safety of the newly developed device. Based on the ex vivo testing, LARA-K1 can create a safety zone of coagulation. For further assessment of the new device, an in vivo study should be performed.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 10 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 10 100%

Demographic breakdown

Readers by professional status Count As %
Student > Doctoral Student 4 40%
Student > Postgraduate 1 10%
Researcher 1 10%
Unknown 4 40%
Readers by discipline Count As %
Medicine and Dentistry 4 40%
Computer Science 1 10%
Unknown 5 50%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 08 March 2018.
All research outputs
#19,951,180
of 25,382,440 outputs
Outputs from Brazilian Journal of Medical and Biological Research
#871
of 1,254 outputs
Outputs of similar age
#325,409
of 449,550 outputs
Outputs of similar age from Brazilian Journal of Medical and Biological Research
#43
of 85 outputs
Altmetric has tracked 25,382,440 research outputs across all sources so far. This one is in the 18th percentile – i.e., 18% of other outputs scored the same or lower than it.
So far Altmetric has tracked 1,254 research outputs from this source. They receive a mean Attention Score of 4.9. This one is in the 28th percentile – i.e., 28% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 449,550 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 23rd percentile – i.e., 23% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 85 others from the same source and published within six weeks on either side of this one. This one is in the 48th percentile – i.e., 48% of its contemporaries scored the same or lower than it.