↓ Skip to main content

Wound healing treatment by high frequency ultrasound, microcurrent, and combined therapy modifies the immune response in rats

Overview of attention for article published in Brazilian Journal of Physical Therapy, April 2016
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age

Mentioned by

twitter
2 X users

Readers on

mendeley
60 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Wound healing treatment by high frequency ultrasound, microcurrent, and combined therapy modifies the immune response in rats
Published in
Brazilian Journal of Physical Therapy, April 2016
DOI 10.1590/bjpt-rbf.2014.0141
Pubmed ID
Authors
Abstract

Therapeutic high-frequency ultrasound, microcurrent, and a combination of the two have been used as potential interventions in the soft tissue healing process, but little is known about their effect on the immune system. To evaluate the effects of therapeutic high frequency ultrasound, microcurrent, and the combined therapy of the two on the size of the wound area, peritoneal macrophage function, CD4+ and CD8+, T lymphocyte populations, and plasma concentration of interleukins (ILs). Sixty-five Wistar rats were randomized into five groups, as follows: uninjured control (C, group 1), lesion and no treatment (L, group 2), lesion treated with ultrasound (LU, group 3), lesion treated with microcurrent (LM, group 4), and lesion treated with combined therapy (LUM, group 5). For groups 3, 4 and 5, treatment was initiated 24 hours after surgery under anesthesia and each group was allocated into three different subgroups (n=5) to allow for the use of the different therapy resources at on days 3, 7 and 14 Photoplanimetry was performed daily. After euthanasia, blood was collected for immune analysis. Ultrasound increased the phagocytic capacity and the production of nitric oxide by macrophages and induced the reduction of CD4+ cells, the CD4+/CD8+ ratio, and the plasma concentration of IL-1β. Microcurrent and combined therapy decreased the production of superoxide anion, nitric oxide, CD4+-positive cells, the CD4+/CD8+ ratio, and IL-1β concentration. Therapeutic high-frequency ultrasound, microcurrent, and combined therapy changed the activity of the innate and adaptive immune system during healing process but did not accelerate the closure of the wound.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 60 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Brazil 1 2%
Unknown 59 98%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Bachelor 11 18%
Student > Ph. D. Student 9 15%
Other 5 8%
Researcher 5 8%
Student > Doctoral Student 4 7%
Other 10 17%
Unknown 16 27%
Readers by discipline
Readers by discipline Count As %
Medicine and Dentistry 15 25%
Nursing and Health Professions 10 17%
Engineering 5 8%
Biochemistry, Genetics and Molecular Biology 3 5%
Agricultural and Biological Sciences 3 5%
Other 5 8%
Unknown 19 32%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 2. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 14 September 2017.
All research outputs
#18,575,839
of 27,781,301 outputs
Outputs from Brazilian Journal of Physical Therapy
#74
of 188 outputs
Outputs of similar age
#188,319
of 316,342 outputs
Outputs of similar age from Brazilian Journal of Physical Therapy
#3
of 3 outputs
Altmetric has tracked 27,781,301 research outputs across all sources so far. This one is in the 31st percentile – i.e., 31% of other outputs scored the same or lower than it.
So far Altmetric has tracked 188 research outputs from this source. They receive a mean Attention Score of 3.9. This one is in the 44th percentile – i.e., 44% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 316,342 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 37th percentile – i.e., 37% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 3 others from the same source and published within six weeks on either side of this one.