↓ Skip to main content

The Influence of Mitral Annuloplasty on Left Ventricular Flow Dynamics

Overview of attention for article published in The Annals of Thoracic Surgery, May 2015
Altmetric Badge

Citations

dimensions_citation
35 Dimensions

Readers on

mendeley
42 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
The Influence of Mitral Annuloplasty on Left Ventricular Flow Dynamics
Published in
The Annals of Thoracic Surgery, May 2015
DOI 10.1016/j.athoracsur.2015.02.028
Pubmed ID
Authors

Walter R.T. Witschey, Donald Zhang, Francisco Contijoch, Jeremy R. McGarvey, Madonna Lee, Satoshi Takebayashi, Chikashi Aoki, Yuchi Han, Joyce Han, Alex J. Barker, James J. Pilla, Robert C. Gorman, Joseph H. Gorman

Abstract

Mitral valve (MV) repair using annuloplasty rings is the preferred method of treatment for MV regurgitation, but the impact of annuloplasty ring placement on left ventricular intraventricular flow has not been studied. Annuloplasty rings of varying sizes were placed in 5 healthy sheep (intercommissural ring sizes were 24, 26, 28, 30, and 32 mm), and three-dimensional phase contrast magnetic resonance imaging (4D flow MRI) was performed before and 1 week after ring placement. Normal diastolic flow consisted of diastolic intraventricular vortices that naturally unwound during systole. Postsurgical intraventricular flow was highly disturbed in all sheep, and the disturbance was greatest for undersized rings. Ring size was highly correlated with the diastolic inflow angle (Pearson's r = -0.62, p < 0.1, 95% confidence interval: -0.92 to 0.14). There was a mean angle increase of mean diastolic inflow angle increase of 12.3 degrees (< 30 mm, p < 0.01, 95% confidence interval: 4.8 to 19.6) for rings less than 30 mm. There was an inverse relationship between peak velocity and annuloplasty ring area (Pearson's r = -0.80, p < 0.05, 95% confidence interval: -0.96 to -0.2). Transmitral pressure gradients increased significantly from baseline 0.73 ± 0.18 mm Hg to after annuloplasty 2.31 ± 1.04 mm Hg (p < 0.05). Mitral valve annuloplasty ring placement disturbs normal left ventricular intraventricular flow patterns, and the degree of disturbance is closely associated with annuloplasty ring size.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 42 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
United States 1 2%
Belgium 1 2%
Unknown 40 95%

Demographic breakdown

Readers by professional status Count As %
Researcher 12 29%
Student > Ph. D. Student 9 21%
Other 5 12%
Student > Doctoral Student 3 7%
Student > Postgraduate 3 7%
Other 7 17%
Unknown 3 7%
Readers by discipline Count As %
Medicine and Dentistry 22 52%
Engineering 8 19%
Agricultural and Biological Sciences 2 5%
Physics and Astronomy 1 2%
Computer Science 1 2%
Other 0 0%
Unknown 8 19%