Comparison of corneal power obtained from VERION image-guided surgery system and four other devices
|
---|---|
Published in |
Clinical Ophthalmology, July 2017
|
DOI | 10.2147/opth.s137878 |
Pubmed ID | |
Authors |
Hung-Yuan Lin, Hsin-Yang Chen, Han Bor Fam, Ya-Jung Chuang, Ronald Yeoh, Pi-Jung Lin |
Abstract |
To assess the corneal keratometric values obtained using the VERION image-guided surgery system and other devices. This study evaluated the right eyes of 115 cataract patients before intraocular lens (IOL) implantation through consecutive tests using 5 devices: VERION Reference Unit, Placido-based corneal topography (OPD-Scan III), monochromatic light-emitting diodes (LenStar LS900 and AL-Scan), and rotary prism technology (auto kerato-refractometer KR-8800). Analyzed parameters were corneal steep and flat keratometric values (Ks and Kf) and corneal astigmatism and axis. These parameters were evaluated using the one-sample two-tailed t-test and the 95% limits of agreement (95% LOAs) between the devices. The mean corneal cylinder value measurements were -0.97±0.63 D, -0.88±0.60 D, -0.90±0.69 D, -0.90±0.67 D, and -0.83±0.60 D with VERION, LenStar, AL-Scan (2.4 mm), OPD III, and KR-8800, respectively. Only KR-8800 showed a significant difference from VERION in the corneal cylinder value (P<0.05). The mean differences in the Kf and Ks of VERION compared to those of OPD III were 0.18±0.45 D and 0.17±0.38 D (P<0.05), respectively. The 95% LOAs of Bland-Altman analysis for the corneal astigmatism axis of the VERION with LenStar, AL-Scan (2.4 mm), OPD III, and KR-8800 were -26.25° to 58.71°, -20.61° to 47.44°, -25.03° to 58.98°, and -27.85° to 65.17°, respectively. None of the VERION parameters were significantly different from those of AL-Scan and LenStar. AL-Scan (2.4 mm zone) was especially similar to VERION. Wide LOAs are potential contributors to axis error in patients with toric IOL implants. |
Twitter Demographics
Geographical breakdown
Country | Count | As % |
---|---|---|
Unknown | 1 | 100% |
Demographic breakdown
Type | Count | As % |
---|---|---|
Members of the public | 1 | 100% |
Mendeley readers
Geographical breakdown
Country | Count | As % |
---|---|---|
Unknown | 23 | 100% |
Demographic breakdown
Readers by professional status | Count | As % |
---|---|---|
Other | 6 | 26% |
Student > Master | 3 | 13% |
Student > Postgraduate | 2 | 9% |
Researcher | 2 | 9% |
Student > Bachelor | 2 | 9% |
Other | 3 | 13% |
Unknown | 5 | 22% |
Readers by discipline | Count | As % |
---|---|---|
Medicine and Dentistry | 16 | 70% |
Nursing and Health Professions | 1 | 4% |
Unspecified | 1 | 4% |
Unknown | 5 | 22% |