↓ Skip to main content

Cyclodestructive procedures for non‐refractory glaucoma

Overview of attention for article published in Cochrane database of systematic reviews, April 2018
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (83rd percentile)
  • Average Attention Score compared to outputs of the same age and source

Mentioned by

policy
1 policy source
twitter
10 X users
wikipedia
2 Wikipedia pages

Citations

dimensions_citation
35 Dimensions

Readers on

mendeley
160 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Cyclodestructive procedures for non‐refractory glaucoma
Published in
Cochrane database of systematic reviews, April 2018
DOI 10.1002/14651858.cd009313.pub2
Pubmed ID
Authors

Manuele Michelessi, Amanda K Bicket, Kristina Lindsley

Abstract

Glaucoma is a leading cause of blindness worldwide. It results in a progressive loss of peripheral vision and, in late stages, loss of central vision leading to blindness. Early treatment of glaucoma aims to prevent or delay vision loss. Elevated intraocular pressure (IOP) is the main causal modifiable risk factor for glaucoma. Aqueous outflow obstruction is the main cause of IOP elevation, which can be mitigated either by increasing outflow or reducing aqueous humor production. Cyclodestructive procedures use various methods to target and destroy the ciliary body epithelium, the site of aqueous humor production, thereby lowering IOP. The most common approach is laser cyclophotocoagulation. To assess the effectiveness and safety of cyclodestructive procedures for the management of non-refractory glaucoma (i.e. glaucoma in an eye that has not undergone incisional glaucoma surgery). We also aimed to compare the effect of different routes of administration, laser delivery instruments, and parameters of cyclophotocoagulation with respect to IOP control, visual acuity, pain control, and adverse events. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2017, Issue 8); Ovid MEDLINE; Embase.com; LILACS; the metaRegister of Controlled Trials (mRCT) and ClinicalTrials.gov. The date of the search was 7 August 2017. We also searched the reference lists of reports from included studies. We included randomized controlled trials of participants who had undergone cyclodestruction as a primary treatment for glaucoma. We included only head-to-head trials that had compared cyclophotocoagulation to other procedural interventions, or compared cyclophotocoagulation using different types of lasers, delivery methods, parameters, or a combination of these factors. Two review authors independently screened search results, assessed risks of bias, extracted data, and graded the certainty of the evidence in accordance with Cochrane standards. We included one trial (92 eyes of 92 participants) that evaluated the efficacy of diode transscleral cyclophotocoagulation (TSCPC) as primary surgical therapy. We identified no other eligible ongoing or completed trial. The included trial compared low-energy versus high-energy TSCPC in eyes with primary open-angle glaucoma. The trial was conducted in Ghana and had a mean follow-up period of 13.2 months post-treatment. In this trial, low-energy TSCPC was defined as 45.0 J delivered, high-energy as 65.5 J delivered; it is worth noting that other trials have defined high- and low-energy TSCPC differently. We assessed this trial to have had low risk of selection bias and reporting bias, unclear risk of performance bias, and high risk of detection bias and attrition bias. Trial authors excluded 13 participants with missing follow-up data; the analyses therefore included 40 (85%) of 47 participants in the low-energy group and 39 (87%) of 45 participants in the high-energy group.Control of IOP, defined as a decrease in IOP by 20% from baseline value, was achieved in 47% of eyes, at similar rates in the low-energy group and the high-energy groups; the small study size creates uncertainty about the significance of the difference, if any, between energy settings (risk ratio (RR) 1.03, 95% confidence interval (CI) 0.64 to 1.65; 79 participants; low-certainty evidence). The difference in effect between energy settings based on mean decrease in IOP, if any exists, also was uncertain (mean difference (MD) -0.50 mmHg, 95% CI -5.79 to 4.79; 79 participants; low-certainty evidence).Decreased vision was defined as the proportion of participants with a decrease of 2 or more lines on the Snellen chart or one or more categories of visual acuity when unable to read the eye chart. Twenty-three percent of eyes had a decrease in vision. The size of any difference between the low-energy group and the high-energy group was uncertain (RR 1.22, 95% CI 0.54 to 2.76; 79 participants; low-certainty evidence). Data were not available for mean visual acuity and proportion of participants with vision change defined as greater than 1 line on the Snellen chart.The difference in the mean number of glaucoma medications used after cyclophotocoagulation was similar when comparing treatment groups (MD 0.10, 95% CI -0.43 to 0.63; 79 participants; moderate-certainty evidence). Twenty percent of eyes were retreated; the estimated effect of energy settings on the need for retreatment was inconclusive (RR 0.76, 95% CI 0.31 to 1.84; 79 participants; low-certainty evidence). No data for visual field, cost effectiveness, or quality-of-life outcomes were reported by the trial investigators.Adverse events were reported for the total study population, rather than by treatment group. The trial authors stated that most participants reported mild to moderate pain after the procedure, and many had transient conjunctival burns (percentages not reported). Severe iritis occurred in two eyes and hyphema occurred in three eyes. No instances of hypotony or phthisis bulbi were reported. The only adverse outcome that was reported by the treatment group was atonic pupil (RR 0.89 in the low-energy group, 95% CI 0.47 to 1.68; 92 participants; low-certainty evidence). There is insufficient evidence to evaluate the relative effectiveness and safety of cyclodestructive procedures for the primary procedural management of non-refractory glaucoma. Results from the one included trial did not compare cyclophotocoagulation to other procedural interventions and yielded uncertainty about any difference in outcomes when comparing low-energy versus high-energy diode TSCPC. Overall, the effect of laser treatment on IOP control was modest and the number of eyes experiencing vision loss was limited. More research is needed specific to the management of non-refractory glaucoma.

X Demographics

X Demographics

The data shown below were collected from the profiles of 10 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 160 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 160 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 21 13%
Student > Bachelor 15 9%
Other 13 8%
Student > Ph. D. Student 13 8%
Student > Postgraduate 11 7%
Other 27 17%
Unknown 60 38%
Readers by discipline Count As %
Medicine and Dentistry 54 34%
Nursing and Health Professions 16 10%
Psychology 6 4%
Social Sciences 4 3%
Neuroscience 3 2%
Other 11 7%
Unknown 66 41%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 13. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 04 December 2023.
All research outputs
#2,840,617
of 25,461,852 outputs
Outputs from Cochrane database of systematic reviews
#5,536
of 12,090 outputs
Outputs of similar age
#57,032
of 339,991 outputs
Outputs of similar age from Cochrane database of systematic reviews
#106
of 157 outputs
Altmetric has tracked 25,461,852 research outputs across all sources so far. Compared to these this one has done well and is in the 88th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 12,090 research outputs from this source. They typically receive a lot more attention than average, with a mean Attention Score of 38.2. This one has gotten more attention than average, scoring higher than 56% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 339,991 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 83% of its contemporaries.
We're also able to compare this research output to 157 others from the same source and published within six weeks on either side of this one. This one is in the 32nd percentile – i.e., 32% of its contemporaries scored the same or lower than it.