↓ Skip to main content

Experimental knee pain impairs submaximal force steadiness in isometric, eccentric, and concentric muscle actions

Overview of attention for article published in Arthritis Research & Therapy, September 2015
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
29 Dimensions

Readers on

mendeley
109 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Experimental knee pain impairs submaximal force steadiness in isometric, eccentric, and concentric muscle actions
Published in
Arthritis Research & Therapy, September 2015
DOI 10.1186/s13075-015-0768-1
Pubmed ID
Authors

David A. Rice, Peter J. McNair, Gwyn N. Lewis, Jamie Mannion

Abstract

Populations with knee joint damage, including arthritis, have noted impairments in the regulation of submaximal muscle force. It is difficult to determine the exact cause of such impairments given the joint pathology and associated neuromuscular adaptations. Experimental pain models that have been used to isolate the effects of pain on muscle force regulation have shown impaired force steadiness during acute pain. However, few studies have examined force regulation during dynamic contractions, and these findings have been inconsistent. The goal of the current study was to examine the effect of experimental knee joint pain on submaximal quadriceps force regulation during isometric and dynamic contractions. The study involved fifteen healthy participants. Participants were seated in an isokinetic dynamometer. Knee extensor force matching tasks were completed in isometric, eccentric, and concentric muscle contraction conditions. The target force was set to 10 % of maximum for each contraction type. Hypertonic saline was then injected into the infrapatella fat pad to generate acute joint pain. The force matching tasks were repeated during pain and once more 5 min after pain had subsided. Hypertonic saline resulted in knee pain with an average peak pain rating of 5.5 ± 2.1 (0-10 scale) that lasted for 18 ± 4 mins. Force steadiness significantly reduced during pain across all three muscle contraction conditions. There was a trend to increased force matching error during pain but this was not significant. Experimental knee pain leads to impaired quadriceps force steadiness during isometric, eccentric, and concentric contractions, providing further evidence that joint pain directly affects motor performance. Given the established relationship between submaximal muscle force steadiness and function, such an effect may be detrimental to the performance of tasks in daily life. In order to restore motor performance in people with painful arthritic conditions of the knee, it may be important to first manage their pain more effectively.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 109 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
United Kingdom 1 <1%
Germany 1 <1%
Unknown 107 98%

Demographic breakdown

Readers by professional status Count As %
Student > Master 26 24%
Researcher 12 11%
Student > Ph. D. Student 11 10%
Student > Doctoral Student 6 6%
Other 5 5%
Other 19 17%
Unknown 30 28%
Readers by discipline Count As %
Nursing and Health Professions 24 22%
Medicine and Dentistry 19 17%
Sports and Recreations 12 11%
Psychology 4 4%
Neuroscience 3 3%
Other 9 8%
Unknown 38 35%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 20 September 2015.
All research outputs
#20,656,820
of 25,374,917 outputs
Outputs from Arthritis Research & Therapy
#2,906
of 3,381 outputs
Outputs of similar age
#205,543
of 280,482 outputs
Outputs of similar age from Arthritis Research & Therapy
#67
of 80 outputs
Altmetric has tracked 25,374,917 research outputs across all sources so far. This one is in the 10th percentile – i.e., 10% of other outputs scored the same or lower than it.
So far Altmetric has tracked 3,381 research outputs from this source. They typically receive more attention than average, with a mean Attention Score of 9.2. This one is in the 7th percentile – i.e., 7% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 280,482 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 14th percentile – i.e., 14% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 80 others from the same source and published within six weeks on either side of this one. This one is in the 5th percentile – i.e., 5% of its contemporaries scored the same or lower than it.