↓ Skip to main content

Trece tratamientos de la insuficiencia renal aguda secundaria a mieloma múltiple con filtros de high cut off

Overview of attention for article published in Nefrología (Madrid), July 2016
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age
  • Average Attention Score compared to outputs of the same age and source

Mentioned by

twitter
2 X users

Citations

dimensions_citation
6 Dimensions

Readers on

mendeley
17 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Trece tratamientos de la insuficiencia renal aguda secundaria a mieloma múltiple con filtros de high cut off
Published in
Nefrología (Madrid), July 2016
DOI 10.1016/j.nefro.2016.03.011
Pubmed ID
Authors

Ana Berni Wennekers, María Pilar Martín Azara, Victoria Dourdil Sahun, Beatriz Bergasa Liberal, José Esteban Ruiz Laiglesia, Patricia Vernet Perna, Rafael Alvarez Lipe

Abstract

Multiple myeloma (MM) is a haematological tumour that is characterised by uncontrolled proliferation of plasma cells and a significant volume of serum free light chains (sFLCs), which can cause acute renal failure due to intratubular precipitation, resulting in cast nephropathy. Acute renal failure is a complication that can arise in more than 20% of patients with multiple myeloma, half of which will require dialysis. We report our experience with 13 patients who were treated with dialysis using high cut off filters (HCO) between July 2011 and February 2015. A total of 6 consecutive 6-hour sessions were performed using a 2.1 m(2) HCO filter (Theralite® by Gambro®). Afterwards, further 6-hour sessions were continued on alternate days. A total of 151 sessions were conducted, with an average of 11.6 sessions per patient (range 6-27). The treatment proved to be effective in removing both kappa and lambda sFLCs, resulting in a 93.7% fall in sFLCs by the end of treatment. The average reduction was 57.7% per dialysis session. 10 out of the 13 cases recovered sufficient renal function to become independent of dialysis. There were no major changes in albumin levels using an infusion protocol of 2 50-mL vials of 20% albumin at the end of the dialysis session. Combination treatment with chemotherapy and long dialysis with HCO filters was effective in reducing the sFLC levels and recovering sufficient renal function in 77% of cases. With HCO filters, significant cost savings are achieved, contrary to what was previously believed.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 17 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 17 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 2 12%
Student > Doctoral Student 2 12%
Other 1 6%
Professor 1 6%
Researcher 1 6%
Other 0 0%
Unknown 10 59%
Readers by discipline Count As %
Medicine and Dentistry 4 24%
Nursing and Health Professions 2 12%
Unknown 11 65%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 2. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 21 November 2017.
All research outputs
#16,462,378
of 25,986,827 outputs
Outputs from Nefrología (Madrid)
#2
of 20 outputs
Outputs of similar age
#218,605
of 369,392 outputs
Outputs of similar age from Nefrología (Madrid)
#6
of 12 outputs
Altmetric has tracked 25,986,827 research outputs across all sources so far. This one is in the 34th percentile – i.e., 34% of other outputs scored the same or lower than it.
So far Altmetric has tracked 20 research outputs from this source. They receive a mean Attention Score of 0.6. This one scored the same or higher as 18 of them.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 369,392 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 38th percentile – i.e., 38% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 12 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 50% of its contemporaries.