↓ Skip to main content

Validation of a Step Detection Algorithm during Straight Walking and Turning in Patients with Parkinson’s Disease and Older Adults Using an Inertial Measurement Unit at the Lower Back

Overview of attention for article published in Frontiers in Neurology, September 2017
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (84th percentile)
  • High Attention Score compared to outputs of the same age and source (89th percentile)

Mentioned by

twitter
19 X users

Citations

dimensions_citation
83 Dimensions

Readers on

mendeley
225 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Validation of a Step Detection Algorithm during Straight Walking and Turning in Patients with Parkinson’s Disease and Older Adults Using an Inertial Measurement Unit at the Lower Back
Published in
Frontiers in Neurology, September 2017
DOI 10.3389/fneur.2017.00457
Pubmed ID
Authors

Minh H. Pham, Morad Elshehabi, Linda Haertner, Silvia Del Din, Karin Srulijes, Tanja Heger, Matthis Synofzik, Markus A. Hobert, Gert S. Faber, Clint Hansen, Dina Salkovic, Joaquim J. Ferreira, Daniela Berg, Álvaro Sanchez-Ferro, Jaap H. van Dieën, Clemens Becker, Lynn Rochester, Gerhard Schmidt, Walter Maetzler

Abstract

Inertial measurement units (IMUs) positioned on various body locations allow detailed gait analysis even under unconstrained conditions. From a medical perspective, the assessment of vulnerable populations is of particular relevance, especially in the daily-life environment. Gait analysis algorithms need thorough validation, as many chronic diseases show specific and even unique gait patterns. The aim of this study was therefore to validate an acceleration-based step detection algorithm for patients with Parkinson's disease (PD) and older adults in both a lab-based and home-like environment. In this prospective observational study, data were captured from a single 6-degrees of freedom IMU (APDM) (3DOF accelerometer and 3DOF gyroscope) worn on the lower back. Detection of heel strike (HS) and toe off (TO) on a treadmill was validated against an optoelectronic system (Vicon) (11 PD patients and 12 older adults). A second independent validation study in the home-like environment was performed against video observation (20 PD patients and 12 older adults) and included step counting during turning and non-turning, defined with a previously published algorithm. A continuous wavelet transform (cwt)-based algorithm was developed for step detection with very high agreement with the optoelectronic system. HS detection in PD patients/older adults, respectively, reached 99/99% accuracy. Similar results were obtained for TO (99/100%). In HS detection, Bland-Altman plots showed a mean difference of 0.002 s [95% confidence interval (CI) -0.09 to 0.10] between the algorithm and the optoelectronic system. The Bland-Altman plot for TO detection showed mean differences of 0.00 s (95% CI -0.12 to 0.12). In the home-like assessment, the algorithm for detection of occurrence of steps during turning reached 90% (PD patients)/90% (older adults) sensitivity, 83/88% specificity, and 88/89% accuracy. The detection of steps during non-turning phases reached 91/91% sensitivity, 90/90% specificity, and 91/91% accuracy. This cwt-based algorithm for step detection measured at the lower back is in high agreement with the optoelectronic system in both PD patients and older adults. This approach and algorithm thus could provide a valuable tool for future research on home-based gait analysis in these vulnerable cohorts.

X Demographics

X Demographics

The data shown below were collected from the profiles of 19 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 225 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 225 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 42 19%
Researcher 27 12%
Student > Bachelor 24 11%
Student > Master 20 9%
Student > Doctoral Student 19 8%
Other 33 15%
Unknown 60 27%
Readers by discipline Count As %
Engineering 38 17%
Neuroscience 29 13%
Medicine and Dentistry 28 12%
Computer Science 12 5%
Nursing and Health Professions 9 4%
Other 30 13%
Unknown 79 35%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 13. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 03 December 2017.
All research outputs
#2,483,791
of 22,999,744 outputs
Outputs from Frontiers in Neurology
#1,350
of 11,899 outputs
Outputs of similar age
#49,388
of 315,688 outputs
Outputs of similar age from Frontiers in Neurology
#22
of 200 outputs
Altmetric has tracked 22,999,744 research outputs across all sources so far. Compared to these this one has done well and is in the 89th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 11,899 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 7.3. This one has done well, scoring higher than 88% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 315,688 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 84% of its contemporaries.
We're also able to compare this research output to 200 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 89% of its contemporaries.