↓ Skip to main content

Performance of the linear ion trap Orbitrap mass analyzer for qualitative and quantitative analysis of drugs of abuse and relevant metabolites in sewage water

Overview of attention for article published in Analytica Chimica Acta, January 2013
Altmetric Badge

Mentioned by

facebook
1 Facebook page

Citations

dimensions_citation
68 Dimensions

Readers on

mendeley
137 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Performance of the linear ion trap Orbitrap mass analyzer for qualitative and quantitative analysis of drugs of abuse and relevant metabolites in sewage water
Published in
Analytica Chimica Acta, January 2013
DOI 10.1016/j.aca.2013.01.010
Pubmed ID
Authors

Lubertus Bijlsma, Erik Emke, Félix Hernández, Pim de Voogt

Abstract

This work illustrates the potential of liquid chromatography coupled to a hybrid linear ion trap Fourier Transform Orbitrap mass spectrometer for the simultaneous identification and quantification of 24 drugs of abuse and relevant metabolites in sewage water. The developed methodology consisted of automatic solid-phase extraction using Oasis HLB cartridges, chromatographic separation of the targeted drugs, full-scan accurate mass data acquisition under positive electrospray ionization mode over an m/z range of 50-600Da at a resolution of 30,000 FWHM and simultaneous MS(n) measurements to obtain information of fragment ions generated in the linear ion trap. Accurate mass of the protonated molecule, together with at least one nominal mass product ion and retention time allowed the confident identification of the compounds detected in these complex matrices. In addition to the highly reliable qualitative analysis, Orbitrap analyzer also proved to have satisfactory potential for quantification at sub-ppb analyte levels, a possibility that has been very little explored in the literature until now. The limits of quantification ranged from 4 to 68ngL(-1) in influent sewage water, and from 2 to 35ngL(-1) in effluent, with the exception of MDA, morphine and THC that presented higher values as a consequence of the high ionization suppression in this type of samples. Satisfactory recoveries (70-120%) and precision (<30%) for the overall procedure were obtained for all compounds with the exception of meta-chlorophenylpiperazine, methylphenidate and ketamine. Isotope-labelled internal standards were added to sewage samples as surrogates in order to correct for matrix effects and also for possible losses during sample treatment. The methodology developed was applied to sewage water samples from the Netherlands (influent and effluent), and the results were compared with those obtained by LC-MS/MS with triple quadrupole. Several drugs of abuse could be identified and quantified, mainly MDMA, benzoylecgonine, codeine, oxazepam and temazepam. Orbitrap also showed potential for retrospective investigation of ketamine metabolites in the samples without the need of additional analysis.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 137 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Russia 1 <1%
Switzerland 1 <1%
Unknown 135 99%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 33 24%
Student > Master 24 18%
Researcher 14 10%
Student > Bachelor 14 10%
Other 8 6%
Other 19 14%
Unknown 25 18%
Readers by discipline Count As %
Chemistry 39 28%
Environmental Science 24 18%
Agricultural and Biological Sciences 7 5%
Psychology 6 4%
Medicine and Dentistry 6 4%
Other 18 13%
Unknown 37 27%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 03 February 2014.
All research outputs
#22,758,309
of 25,373,627 outputs
Outputs from Analytica Chimica Acta
#6,707
of 7,520 outputs
Outputs of similar age
#261,579
of 292,930 outputs
Outputs of similar age from Analytica Chimica Acta
#72
of 74 outputs
Altmetric has tracked 25,373,627 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 7,520 research outputs from this source. They receive a mean Attention Score of 3.3. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 292,930 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 74 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.