↓ Skip to main content

Real-time surveillance of left atrial appendage thrombus during contrast computed tomography imaging for catheter ablation: THe Reliability of cOMputed tomography Beyond UltraSound in THROMBUS…

Overview of attention for article published in Journal of Thrombosis and Thrombolysis, September 2018
Altmetric Badge

About this Attention Score

  • Good Attention Score compared to outputs of the same age (66th percentile)
  • Good Attention Score compared to outputs of the same age and source (68th percentile)

Mentioned by

twitter
6 X users

Readers on

mendeley
15 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Real-time surveillance of left atrial appendage thrombus during contrast computed tomography imaging for catheter ablation: THe Reliability of cOMputed tomography Beyond UltraSound in THROMBUS detection (THROMBUS) study
Published in
Journal of Thrombosis and Thrombolysis, September 2018
DOI 10.1007/s11239-018-1742-y
Pubmed ID
Authors

Tetsuma Kawaji, Hitomi Numamoto, Shintaro Yamagami, Ryu Mabuchi, Takaaki Kitamura, Naomi Enoki, Koji Koizumi, Shotaro Kanao, Masashi Kato, Takafumi Yokomatsu, Satoshi Shizuta, Shinji Miki, Koh Ono, Kaori Togashi, Takeshi Kimura

Abstract

Left atrial contrast computed tomography (LA-CT) as well as transesophageal echocardiography (TEE) can exclude left atrial appendage (LAA) thrombus, but is sometimes unable to evaluate LAA due to incomplete LAA filling. The aim of the current study was to validate the utility of real-time approach of LA-CT with real-time surveillance of LAA-filling defect (FD). We enrolled consecutive 894 patients with LA-CT studies acquired for catheter ablation and compared the diagnostic accuracy in demonstrating LAA-FD between conventional protocol (N = 474) and novel protocol with real-time surveillance of LAA-FD immediately after the initial scanning and, when necessary, adding delayed scanning in the supine or prone position (N = 420). Primary endpoint was severity of LAA-FD classified into the 3 groups: "Grade-0" for complete filling of contrast, "Grade-1" for incomplete filling of contrast, and "Grade-2" for complete FD of contrast. The prevalence of Grade-1 and Grade-2 FD was 17.3% and 11.2% in conventional protocol, whereas there was no patient with Grade-2 FD, and only 1 patient with Grade-1 FD after the additional scanning in novel protocol. In 5 patients with suspected LAA thrombus both by TEE and Grade-2 FD in LA-CT by the conventional protocol, ablation procedure was canceled due to diagnosis of LAA thrombus. Conversely, 4 patients with suspected LAA thrombus by TEE in novel protocol group was proved to have intact LAA by LA-CT with and without additional scanning. This novel approach with real-time surveillance improved the diagnostic accuracy of LA-CT in detecting LAA-FD, suggesting potential superiority of LA-CT over TEE in excluding LAA thrombus.

X Demographics

X Demographics

The data shown below were collected from the profiles of 6 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 15 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 15 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 3 20%
Student > Bachelor 2 13%
Student > Master 2 13%
Student > Doctoral Student 1 7%
Student > Ph. D. Student 1 7%
Other 3 20%
Unknown 3 20%
Readers by discipline Count As %
Medicine and Dentistry 11 73%
Unknown 4 27%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 5. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 07 June 2023.
All research outputs
#6,954,842
of 24,938,276 outputs
Outputs from Journal of Thrombosis and Thrombolysis
#270
of 1,050 outputs
Outputs of similar age
#115,508
of 346,633 outputs
Outputs of similar age from Journal of Thrombosis and Thrombolysis
#6
of 16 outputs
Altmetric has tracked 24,938,276 research outputs across all sources so far. This one has received more attention than most of these and is in the 72nd percentile.
So far Altmetric has tracked 1,050 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 7.1. This one has gotten more attention than average, scoring higher than 74% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 346,633 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 66% of its contemporaries.
We're also able to compare this research output to 16 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 68% of its contemporaries.