Predictors of intraoperative electrosurgery-induced implantable cardioverter defibrillator (ICD) detection

Overview of attention for article published in Journal of Interventional Cardiac Electrophysiology, September 2016
Altmetric Badge

Mentioned by

twitter
5 X users

Readers on

mendeley
27 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Predictors of intraoperative electrosurgery-induced implantable cardioverter defibrillator (ICD) detection
Published in
Journal of Interventional Cardiac Electrophysiology, September 2016
DOI 10.1007/s10840-016-0184-8
Pubmed ID
Authors

Hannah Friedman, John V. Higgins, James D. Ryan, Thomas Konecny, Samuel J. Asirvatham, Yong-Mei Cha

Abstract

In the USA, the number of people needing implantable cardioverter defibrillators (ICDs) has grown dramatically. Many ICD recipients will need to undergo a surgical procedure at some point following ICD implantation. Most surgeries involve the use of electrocautery. Currently, the effects of electrocautery-induced electromagnetic interference (EI-EMI) on ICDs are poorly understood. The aim of this study was to study EI-EMI using prospectively collected clinical data. We analyzed prospectively collected ICD data from patients undergoing a surgical procedure at Mayo Clinic between 2011 and 2012. Information on clinical, device history, device interrogation pre- and post-surgery, and surgical information were collected for all patients. ICDs were programmed with detections on and therapies off. The patients were then categorized into two groups: those with EI-EMI inappropriate arrhythmia detection and those without detection. The stored electrograms were reviewed. Clinical and device parameters were analyzed to identify predictors of EI-EMI. Of 103 patients studied, bipolar cautery did not induce EI-EMI (0/11 cases), whereas monopolar cautery resulted in noise detection in 11/92 procedures. Among 11 inappropriate episodes of detection, 10 had surgery at chest, neck, and upper extremity sites with cautery current across the ICD lead tip; 1 had abdominal surgery; and none had back or low extremity surgery. On average, the near-field electrogram amplitude values were greater than the far-field amplitude values. EI-EMI does not occur when bipolar cautery or monopolar cautery is used below the hips with the dispersive ground pad applied to the lower extremities. In contrast to external EMI, EI-EMI may be larger on near-field than far-field electrograms.

X Demographics

X Demographics

The data shown below were collected from the profiles of 5 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 27 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 27 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 4 15%
Other 3 11%
Student > Ph. D. Student 3 11%
Student > Master 3 11%
Student > Postgraduate 2 7%
Other 5 19%
Unknown 7 26%
Readers by discipline Count As %
Medicine and Dentistry 10 37%
Engineering 3 11%
Computer Science 1 4%
Business, Management and Accounting 1 4%
Sports and Recreations 1 4%
Other 1 4%
Unknown 10 37%