↓ Skip to main content

Scintigraphic evaluation of oesophageal transit during radiotherapy to the mediastinum

Overview of attention for article published in BMC Gastroenterology, November 2008
Altmetric Badge

Citations

dimensions_citation
7 Dimensions

Readers on

mendeley
11 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Scintigraphic evaluation of oesophageal transit during radiotherapy to the mediastinum
Published in
BMC Gastroenterology, November 2008
DOI 10.1186/1471-230x-8-51
Pubmed ID
Authors

Giuseppe Sasso, Pierfrancesco Rambaldi, Francesco S Sasso, Vincenzo Cuccurullo, Paola Murino, Paolo Puntieri, Hugo R Marsiglia, Luigi Mansi

Abstract

To quantitatively evaluate radiation-induced impaired oesophageal transit with oesophageal transit scintigraphy and to assess the relationships between acute oesophagitis symptoms and dysmotility. Between January 1996 and November 1998, 11 patients affected by non-small-cell carcinoma of the lung not directly involving the oesophagus, requiring adjuvant external beam radiotherapy (RT) to the mediastinum were enrolled. Oesophageal transit scans with liquid and semisolid bolus were performed at three pre-defined times: before (T0) and during radiation at 10 Gy (T1) and 30 Gy (T2). Two parameters were obtained for evaluation: 1) mean transit time (MTT); and 2) ratio between peak activity and residual activity at 40 seconds (ER-40s). Acute radiation toxicity was scored according to the joint EORTC-RTOG criteria. Mean values with standard deviation were calculated for all parameters. Analysis of variance (ANOVA) tests and paired t-Tests for all values were performed. An increase in the ER-40s from T0 to T1 or T2 was seen in 9 of 11 patients (82%). The mean ER-40s value for all patients increased from 0.8306 (T0) to 0.8612 (T1) and 0.8658 (T2). These differences were statistically significant (p < 0.05) in two paired t-Tests at T0 versus T2 time: overall mean ER-40s and upright ER-40s (p = 0.041 and p = 0.032, respectively). Seven patients (63%) showed a slight increase in the mean MTT value during irradiation but no statistically significant differences in MTT parameters were found between T0, T1 and T2 (p > 0.05). Using oesophageal scintigraphy we were able to detect early alterations of oesophageal transit during the third week of thoracic RT.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 11 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 11 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 2 18%
Professor > Associate Professor 2 18%
Researcher 2 18%
Student > Ph. D. Student 1 9%
Student > Doctoral Student 1 9%
Other 0 0%
Unknown 3 27%
Readers by discipline Count As %
Medicine and Dentistry 5 45%
Psychology 1 9%
Agricultural and Biological Sciences 1 9%
Unknown 4 36%