↓ Skip to main content

Augmented reality surgical navigation with ultrasound-assisted registration for pedicle screw placement: a pilot study

Overview of attention for article published in International Journal of Computer Assisted Radiology and Surgery, August 2017
Altmetric Badge

About this Attention Score

  • Above-average Attention Score compared to outputs of the same age (63rd percentile)
  • High Attention Score compared to outputs of the same age and source (81st percentile)

Mentioned by

twitter
1 X user
patent
1 patent

Citations

dimensions_citation
102 Dimensions

Readers on

mendeley
111 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Augmented reality surgical navigation with ultrasound-assisted registration for pedicle screw placement: a pilot study
Published in
International Journal of Computer Assisted Radiology and Surgery, August 2017
DOI 10.1007/s11548-017-1652-z
Pubmed ID
Authors

Longfei Ma, Zhe Zhao, Fang Chen, Boyu Zhang, Ligong Fu, Hongen Liao

Abstract

We present a novel augmented reality (AR) surgical navigation system based on ultrasound-assisted registration for pedicle screw placement. This system provides the clinically desired targeting accuracy and reduces radiation exposure. Ultrasound (US) is used to perform registration between preoperative computed tomography (CT) images and patient, and the registration is performed by least-squares fitting of these two three-dimensional (3D) point sets of anatomical landmarks taken from US and CT images. An integral videography overlay device is calibrated to accurately display naked-eye 3D images for surgical navigation. We use a 3.0-mm Kirschner wire (K-wire) instead of a pedicle screw in this study, and the K-wire is calibrated to obtain its orientation and tip location. Based on the above registration and calibration, naked-eye 3D images of the planning path and the spine are superimposed onto patient in situ using our AR navigation system. Simultaneously, a 3D image of the K-wire is overlaid accurately on the real one to guide the insertion procedure. The targeting accuracy is evaluated postoperatively by performing a CT scan. An agar phantom experiment was performed. Eight K-wires were inserted successfully after US-assisted registration, and the mean targeting error and angle error were 3.35 mm and [Formula: see text], respectively. Furthermore, an additional sheep cadaver experiment was performed. Four K-wires were inserted successfully. The mean targeting error was 3.79 mm and the mean angle error was [Formula: see text], and US-assisted registration yielded better targeting results than skin markers-based registration (targeting errors: 2.41 vs. 5.18 mm, angle errors: [Formula: see text] vs. [Formula: see text]. Experimental outcomes demonstrate that the proposed navigation system has acceptable targeting accuracy. In particular, the proposed navigation method reduces repeated radiation exposure to the patient and surgeons. Therefore, it has promising prospects for clinical use.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 111 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 111 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 16 14%
Student > Ph. D. Student 13 12%
Researcher 10 9%
Student > Doctoral Student 9 8%
Other 8 7%
Other 20 18%
Unknown 35 32%
Readers by discipline Count As %
Medicine and Dentistry 29 26%
Engineering 17 15%
Computer Science 12 11%
Business, Management and Accounting 2 2%
Neuroscience 2 2%
Other 10 9%
Unknown 39 35%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 4. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 01 April 2021.
All research outputs
#7,025,826
of 22,996,001 outputs
Outputs from International Journal of Computer Assisted Radiology and Surgery
#200
of 856 outputs
Outputs of similar age
#111,727
of 317,463 outputs
Outputs of similar age from International Journal of Computer Assisted Radiology and Surgery
#3
of 16 outputs
Altmetric has tracked 22,996,001 research outputs across all sources so far. This one has received more attention than most of these and is in the 68th percentile.
So far Altmetric has tracked 856 research outputs from this source. They receive a mean Attention Score of 3.1. This one has done well, scoring higher than 75% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 317,463 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 63% of its contemporaries.